Industrial Door Operator

BS-KGT3-ZIN

Industrial door operator, mechanical limit, manual‑lift, quick‑clutch & overheat protection.

Total unit length: 285 mm Control box: Length 208 mm, Height 48 mm Overall unit height: 244 mm

Built‑in Mechanical Limit,Quick‑clutch,Over‑heat Protection,Manual Emergency Lifting

BS-KGT3-ZIN Industrial Door Operator

35 / 50 N·m | Encoder Limit | 24 rpm Output | Up to 6 m Lifting Height

The BISEN BS-KGT3-ZIN is an encoder-limited industrial door operator with 35 and 50 N·m configurations. Four order codes combine these torque ratings with 220 V or 380 V supplies. Select the exact electrical version and confirm the door balance, shaft and lifting arrangement.

Key Features

  • Encoder limit control and digital position detection.

  • Quick clutch for manual release.

  • Motor overheat protection with a listed 120°C thermal-protection threshold.

  • Self-check, delayed automatic closing and emergency stop.

  • External safety-device connections for a compatible pressure edge, infrared detector and warning light.

Specifications

Parameter

35 / 220 V

50 / 220 V

35S / 380 V

50S / 380 V

Order code

KGT3.35-ZIN

KGT3.50-ZIN

KGT3.35S-ZIN

KGT3.50S-ZIN

Supply voltage / frequency

220 V AC / 50 Hz

220 V AC / 50 Hz

380 V AC / 50 Hz

380 V AC / 50 Hz

Motor power

370 W

450 W

370 W

450 W

Maximum output torque

35 N·m

50 N·m

35 N·m

50 N·m

Output speed

24 rpm

24 rpm

24 rpm

24 rpm

Maximum lifting height

6 m

6 m

6 m

6 m

Thermal protection threshold

120°C

120°C

120°C

120°C

Operating temperature

−20°C to +50°C

−20°C to +50°C

−20°C to +50°C

−20°C to +50°C

Which Configuration Do I Need?

Requirement

Selection / Check

35 N·m requirement

Select .35 / .35S according to the available supply

50 N·m requirement

Select .50 / .50S according to the available supply

Door selection

Confirm balance, area, shaft geometry and required torque for the exact ZIN model

FAQ

Which configurations are available? KGT3.35-ZIN and KGT3.50-ZIN use 220 V supplies, with 35 and 50 N·m respectively. The .35S-ZIN and .50S-ZIN versions use 380 V.

What power frequency is required? The specified power frequency is 50 Hz.

Is 120°C the operating ambient temperature? No. It is the thermal-protection threshold. The specified operating ambient range is −20°C to +50°C.

How should the allowable door area be selected? Confirm the required torque, door balance, shaft arrangement and allowable door area for the exact ZIN order code with BISEN.

About BISEN

BISEN SMART ACCESS is a China-based manufacturer of barrier gates, gate operators and access-control equipment, serving distributors, integrators and contractors worldwide.

Get a quote: Send the exact ZIN order code, supply voltage, door type/area and balance, shaft dimensions, required torque and safety-device requirements.

Company

About Us · Certifications · Global Presence

Products

Gate Openers · Barrier Gates · LPR · Parking Systems

Support

Download Center · Manuals · Certificates · Videos

Contact

info@bisensa.com · www.bisensa.com

© Bisen Smart Access Co., Ltd. Listed on Shenzhen Stock Exchange · 301083